The static load rating of a ball screw, normally shown as C0a or Coa in a catalog, is a reference value used to evaluate whether a stationary, very slow-moving or peak axial load may cause permanent deformation at the contact between the balls and raceways.
It should not be interpreted as the recommended working load. A static safety factor must be applied, and the screw shaft must also be checked for buckling, mounting rigidity and other application limits.
Definition of Basic Static Load Rating C0a
The basic static load rating is the constant axial load at which the combined permanent deformation of the rolling element and raceway at the most heavily stressed contact point reaches approximately 0.0001 times the ball diameter.
This amount of deformation is very small, but an indentation in the raceway can affect the subsequent motion of the ball screw. Possible symptoms include:
- Increased running resistance
- Abnormal vibration or noise
- Reduced motion smoothness
- Loss of positioning consistency
- Accelerated damage at the ball and raceway contact surfaces
For this reason, C0a represents a deformation-based reference rating rather than a load that should be applied directly in normal machine operation.
When Is Static Load Rating Used?
The static load rating requires particular attention when the ball screw is exposed to a high axial force while stationary or moving at very low speed. Typical conditions include:
- A vertical axis holding a load while stopped
- High clamping or pressing force applied at low speed
- Emergency stopping or sudden impact
- Rapid acceleration and deceleration
- Temporary overload during machine setup or a collision
- Transportation or handling loads applied before the machine begins operating
Static does not simply mean that the machine is switched off. Peak loads generated by an emergency stop, impact or sudden change in process force must also be evaluated against the static load capacity.
Static Load Rating Is Not the Permissible Working Load
The permissible maximum axial load can be estimated from the basic static load rating and an appropriate static safety factor:
Permissible static axial load: Fa,max = C0a ÷ fs
Where:
- Fa,max = permissible maximum axial load
- C0a = basic static load rating
- fs = static safety factor
A commonly used lower-limit safety factor is approximately 2 for equipment without vibration or impact and approximately 5 where vibration or impact is present. The final value should be selected according to machine risk, load uncertainty, stopping behavior and the consequences of failure.
DLY SFU1604 Static Load Example
For a DLY SFU1604-4 ball screw, the catalog static load rating is approximately 1,270 kgf. This is an axial force rating; it should not be described simply as a supported mass of 1,270 kg.
| Condition | Static Safety Factor | Calculated Reference Load |
|---|---|---|
| No significant vibration or impact | fs = 2 | 1,270 ÷ 2 = 635 kgf |
| Vibration, impact or uncertain peak loading | fs = 5 | 1,270 ÷ 5 = 254 kgf |
These values illustrate how a safety factor is applied; they are not complete machine load recommendations. For a long screw under compression, the permissible load may be limited by shaft buckling before the ball and raceway contact reaches the catalog static rating.
Static Load Rating vs Dynamic Load Rating
| Parameter | Static Load Rating C0a | Dynamic Load Rating Ca |
|---|---|---|
| Main purpose | Evaluates the risk of permanent contact deformation | Used in nominal fatigue-life calculations |
| Relevant condition | Stationary, very slow motion or peak loading | Repeated operation under axial load |
| Selection method | Compare peak axial load after applying fs | Calculate life from equivalent operating load |
| Primary concern | Permanent indentation or deformation | Rolling-contact fatigue over time |
A ball screw can pass a static-load check but still have insufficient dynamic life. Conversely, a screw selected only from its dynamic rating may be damaged by a short but severe impact load. Both ratings must therefore be checked independently.
For a broader explanation of rated loads and actual machine loads, see the DLY guide to ball screw load capacity.
What Determines the Catalog Static Load Rating?
The C0a value shown in a product table is determined by the internal geometry and load distribution of that particular ball screw assembly. Important design variables include:
- Ball diameter
- Raceway geometry and contact angle
- Number of loaded balls and circulation circuits
- Nut and screw-groove dimensions
- Material and heat-treatment condition
- Manufacturing accuracy and load distribution
Nominal shaft diameter alone is not sufficient for comparison. Two 16 mm ball screws can have different static ratings when their lead, ball diameter, number of circuits or nut construction differs.
For example, DLY reference data list the SFU1605-3 at approximately 1,240 kgf C0a and the SFU1605-4 at approximately 1,790 kgf C0a. Both have a nominal diameter of 16 mm and a 5 mm lead, but the different circuit arrangements result in different load ratings.
You can review these configurations on the DLY 1605 ball screw nut specification page.
Other Limits That Must Be Checked
Static load capacity is only one part of ball screw selection. Before confirming a model, check the following conditions separately:
- Buckling under compression: Long and slender screw shafts may bend under axial compression.
- Dynamic life: Repeated operating loads must be evaluated using the dynamic load rating.
- Permissible speed: Shaft diameter, unsupported length and support arrangement affect critical speed.
- Support-bearing capacity: BK/BF, FK/FF or other support units must be suitable for the applied axial load.
- Acceleration and stopping loads: Peak force may be substantially higher than the steady operating load.
- Mounting alignment: Misalignment can create additional radial force and uneven internal loading.
- Vertical-axis safety: A brake, counterbalance or other holding device may be required because a ball screw can back-drive.
For higher axial-load requirements, review the available high-load ball screw options, but final selection should still be based on the complete operating conditions.
Information Required for Load Verification
To verify whether a ball screw has sufficient static capacity, provide:
- Maximum and normal axial load
- Horizontal or vertical mounting orientation
- Stroke and total screw length
- Operating speed and acceleration
- Expected impact or emergency-stop conditions
- Fixed, supported or free-end arrangement
- Required service life and positioning accuracy
- Ball screw model or dimensional drawing, if already selected
DLY can compare the peak axial load with C0a and also review dynamic load, buckling and speed limits. Send the application parameters rather than selecting a ball screw from static load rating alone.
Contact DLY
Email: export@dlybearing.com